Analysis of the Power Flow of the Gorontalo Electricity System Due to the Entry of 150 KV Industrial Customers

Ilham Ismail, Frengki Eka Putra Surusa, Steven Humena

Abstract


Currently, in Pohuwato Regency, Popayato District, a wood pellet industry factory has been built by PT. Biomass Jaya Abadi (BJA). To meet electricity needs, electrical energy is taken from the PLN electricity supply through a 150 kV high-voltage electricity network and a special substation (GI) is made to serve its electrical energy needs. So it is said to be a high voltage customer. As a result of the entry of these high voltage customers, it will affect the configuration of the existing electrical system. The purpose of this study was to determine the value of voltage, load flow and power losses after the entry of 150 kV high voltage industrial customers. The method used in this study is the Newton Rhapson method with the help of ETAP 19.01 software. From the simulation results with the inclusion of PT. The BJA can improve the voltage profile on each bus of the 150 kV Gorontalo electrical system and 20 kV outgoing. Loss of power loss after the entry of PT. BJA can provide very small comparison percentages. So that it can provide better system capabilities.

Keywords


Voltage Profile; Power Losses and PT. BJA

Full Text:

PDF

References


John J. Grainger and William D. Stevenson, J. (1994). Power System Analysis. Power System Analysis.

Frengki, suyono, W. (2016). Analisis Steady State dan Dinamik pada Perencanaan Pengembangan Pembangkit Sistem Gorontalo. E-JAEI, 9–14.

PT. PLN (PERSERO) ULTG Gorontalo

PT. PLN (PERSERO) UP3 Gorontalo.

Steven, H., Frengki, S., Yusrianto, M & Taufik, L. (2020). Analisa pengaruh peningkatan beban terhadap sistem ketenagalistrikan 150 kV Gorontalo berbasis power system analysis matrix laboratory. Jurnal Teknik Unjani, 19(1) Mei 2020, pp.10-17.

Hariyadi, S. (2017). Analisa Rugi-rugi daya dan Jatuh Tegangan pada Saluran Transmisi Tegangan Tinggi 150 KV pada Gardu Induk Salur-Masaran Disusun. Universitas Muhammadiyah Surakarta, (1–16).

Muhammad Radil, Riad Syech, S. (2014). Analisis Rugi-rugi Daya pada Saluran Transmisi Tegangan 150 kV dari Gardu Induk Koto Panjang ke Gardu Induk Garuda Sakti Pekan Baru. 1(2), 193–198

Dewantara, M. (2018). Analisis Rugi-rugi Daya pada Saluran Transmisi Tegangan Tinggi 150 kV di Gardu Induk Wonogiri sampai Gardu Induk Wonosari. TK Electrical Engineering. Electronic Nuclear Engineering. 2018.

Arikunto, Suharsimi. (2010). Prosedur Pnelitian. Pemanfaatan sofware ETAP Power Station 4.0.0 untuk menganalisa aliran daya listrik di gardu induk ungaran 150 kV. Skripsi. Semarang.

Prabowo. H. (2007). Analisis Aliran Daya di Wilayah Kerja PT. PLN (Persero) UPT Semarang. Skripsi. Semarang : Jurusan Teknik Elektro Universitas Negeri Semarang.

Sigit, A. P. (2015). Analisis Aliran Daya (Load Flow) dalam sistem tenaga listrik menggunakan software ETAP power station 4.0.0 di PT. Kota Jati Furmind Jepara. Skripsi. Semarang : Jurusan Teknik Elektro Universitas Negeri Semarang.

Unggul, D. K (2011). Simulasi Aliran Daya pada Penyulang 2 Gardu Induk Rawalo dengan menggunakan software ETAP 7.0. Jurnal. Semarang : Jurusan teknik Elektro Fakultas Teknik Universitas Diponegoro.

Sulasno. (1993). Analisis Sistem Tenaga Listrik. Semarang : Satya Wacana.

Agus, S & Anggit, P. (2017). Analisis Rugi-rugi Daya pada Transmisi Tegangan Tinggi 150 kV di PLN Sungguminasa. Tugas Akhir. Repository Teknik Elektro Universitas Muhamadiyah Makasar. TK Electrical Engineering. Electronic Nuclear Engineering. 2018.

Yan Budi Haryono. (2017). Simulasi dan Analisa Aliran Daya Sistem Tenaga Listrik 20 kV Region Cilacap menggunakan Meode Newton Rhapson. Skripsi. Repository Teknik Elektro Universitas Muhamadiyah Purwokerto.




DOI: https://doi.org/10.37905/jjeee.v6i2.24795

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Published by:
Electrical Engineering Department
Faculty of Engineering
State University of Gorontalo
Jenderal Sudirman Street No.6, Gorontalo City, Gorontalo Province, Indonesia
Telp. 0435-821175; 081340032063
Email: redaksijjeee@ung.ac.id/redaksijjeee@gmail.com

Creative Commons License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

 

slot gacor slot gacor hari ini slot gacor 2025 demo slot pg slot gacor slot gacor